Marine Construction® Magazine

  • Home
  • RESOURCES
    • EQUIPMENT
    • MATERIALS
    • MANUALS
    • SERVICES
    • LEGAL
    • EDUCATION
    • SAFETY
  • SUBSCRIPTION
    • PREVIOUS ISSUES
  • ADVERTISING
  • WEBINAR
  • VIDEOS
  • CONTACT
  • BLOG
  • Classifieds
  • Jobs
MCMag NEWS
  • Crane Cracks and Fatigue   |   Sep 25 2023

  • The Marine Construction Magazine Conversation with … Women in Engineering    |   Sep 22 2023

  • Alternative Power Trends at The Utility Expo   |   Sep 20 2023

  • Harnessing the ShibataFenderTeam fender system’s safety potential to support offshore wind power supply   |   Sep 20 2023

  • Crowley, BWXT Debut Nuclear Power Generation Vessel Concept   |   Sep 20 2023

  • Funded Alternative Energy Projects Announced – U.S. Department of Energy Map   |   Sep 20 2023

 
You are at :Home»BLOG»WALKWAYS AND HANDRAILS

WALKWAYS AND HANDRAILS

Jul 31 2020 BLOG Comments Off on WALKWAYS AND HANDRAILS 1888 Views

Walkways

  1. Main walkways should not be less than 4 feet wide. The minimum width between berthing slips should not be less than 3 feet when used as access to boats.
  2. Walkways should be kept free from mud, ice, snow, grease, or any other material or obstructions that could create a slipping or tripping hazard.
  3. Walkways should be structurally sound. Flooring or decking should not be less than 1-inch rough, 2 inch by 6 inch S3S, 3/4 inch exterior plywood, or other material capable of supporting a minimum design load of 50 pounds per square foot. The use of composite grating that will not have an uplifting force during periods of flooding or storm surge is strongly recommended.
  4. Walkways should be even, free from protruding bolts and nails, and have a slip- free surface. Carpeting should not be used to provide a non-slip surface.
  5. Walkways from shore-to-dock should have a maximum slope of 3 to 1; be free from excessive spring, deflection, and lateral movement; and be adequately supported with flotation.
  6. Walkways should be above the water level at all times.
  7. Shore-to-dock walkways should have a standard 42-inch high solid handrail with an intermediate rail securely installed on each side.
  8. Where feasible, walkways from shore-to-dock should be constructed to allow access by the handicapped.
  9. Access ways should be adequate for fighting fires as determined by local fire- fighting personnel.
  10. Prominent signage at the beginning at the access walkway should be installed stating that swimming, diving, and running are prohibited.
  11. A gate system to prevent unauthorized access as well as wandering children should be provided.

Handrails

  1. Handrails should be provided on all stairways, walkways, and all office and service docks that are open to the general public.
  2. Handrails should be 42 inches in height, with an intermediate rail approximately 22 inches in height. Where children may be present, a guard between the deck and the lower rail is recommended.
  3. Handrails must be capable of withstanding loads of 200 pounds applied in any direction at any point with a minimum of deflection. They must be structurally sound, maintained in a state of good repair and a minimum size of 2 inch by 4 inch, or equivalent strength material. Posts for handrails should be spaced on no more than 8-foot centers. Handrails should be smooth-surfaced with no protruding upright posts.
  4. Stairways and walkways from shore-to-dock should have handrails on each side of the stairway or walkway.
  5. Office and service docks should have handrails around the outside perimeter of the dock with appropriate openings for boarding and fueling boats. Handrails are required where public exposure warrants them. For example, places on the dock where people tend to congregate or where the walkway is so narrow that two people carrying gear cannot pass each other safely should have handrails. Also, handrails are required where walkways end or make sharp turns that would lead people to walk directly into the water. Handrails are required at the main walkway end of boat storage stalls whenever the dock layout requires shore visitors to pass these openings on their way to other public use facilities.
  6. Gates and signs should be installed to limit access to boat storage and repair areas to authorized personnel only.
2020-07-31
MCMag
Twitter Facebook linkedin Pinterest Email Print More

Authors

Posted by : MCMag
Previous Article :

FIRE PROTECTION

Next Article :

CRANE OPERATION AND ROUTINE SAFETY PROCEDURES

Related Articles

Millwall Outer Dock, London, U.K.

Millwall Outer Dock, London, U.K.

MCMag Jul 05 2023
A scientist’s decades-long portrait of a vanishing Chesapeake island

A scientist’s decades-long portrait of a vanishing Chesapeake island

MCMag Aug 28 2023
Quiet Pile Driving Technology

Quiet Pile Driving Technology

MCMag Mar 20 2020

Advertisement

Current Issue

Current Issue of Marine Construction Magazine Volume IV 2023

Previous Issue

Previous Issue of Marine Construction Magazine Volume III 2023
Marine Construction Magazine Logo Marine Construction® Magazine publishes Six (6) Issues per year, once every 2-Months. We are by no means your typical publication. With over 30,000 readers, we pride ourselves on covering the topics of “actual usefulness” to our readers. Yes, we are a little unorthodox but…we like it like that. The bottom line is, if you are in the Marine Construction or related industry…you’ve come to the right place.

Random Posts

  • OZ Lifting Launches Stainless Steel Chain Hoist 

    OZ Lifting Launches Stainless Steel Chain Hoist 

    MCMag Apr 22 2022
  • Hopper Barge and Tug Capsize, One Drowned  

    Hopper Barge and Tug Capsize, One Drowned  

    MCMag Jul 12 2023
  • MCM Conversation – JD Fields’ Dean Abbondanza  

    MCM Conversation – JD Fields’ Dean Abbondanza  

    MCMag Feb 06 2023

Follow us

Sign up for our eNewsletter

eNewsletter Signup Form
© Copyright 2022, MarineConstruction®Magazine. All Rights Reserved